RENEWABLE ENERGY – HAZARDOUS AREA – INDUSTRIAL AUTOMATION – PANEL BUILDING

All Products

Flterable Category List Of DS Energy Products

Control Solutions

Control System Designs By DS Energy

Junction Boxes

Junction Boxes Supplied By DS Energy

Automation Solutions

Products To Automate Your Process

Enclosures

ATEX Enclosures by DS Energy

Client Solutions

Clients Solutions Developed By DS Energy

In Hire Fleet

Hire Euipment To Reduce Project Costs

Our Brochure

View Our Latest Brochure

DS Energy Services

View Our Services

ATEX System Design

System Designs By Softstart UK

Service Engineers

Softstart UK LV & MC Expert Service Engineers

Product Training

Available Training Services

Panel Design

Comprehensive Panel Designs

Oil & Gas Industry

DS Energy Oil & Gas Industry Services

High Quality Technical Support

Phone Support & Application Selection

Software Design

PLC & HMI Programming, Fieldbus Support

Renewable Energy

View Our Renewable Energy Services

DS Energy Downloads

Download Manuals, Software, Drivers & Code

Support Links

List Of Useful Support Links

Our Distributors

List Of Our Distributors

Our Brochure

View Our Latest Brochure

Project: Compressed air for Vegan food producer

Project Overview

When a new large volume compressed air supply was required for the production process for expanding Northern food producer, the main OEM Atlas Copco decided to return to DS Energy a partner of many years, who had previously supplied 2 x 11kV 1MW DOL starters and a 1MW 3,3kV Soft Starter, for the for the fermentation process.

Challenge:

The new system had to fit into a compact are on the site next to the new compressor installation and work seamlessly with the plant and Atlas Copco BMS / SCADA system. Delivery was critical so we designed and engineered the system in a short period of time delivering the 900kW 3,3kV Soft Starter in 12 weeks.

Solution:

The new starter is fed from an older Schneider feeder VCB, the new Soft Starter gives the older Schneider VCB the available / permissive signal that allows the 3,3kV energisation.

During the start the current is capped at 320% of rated FLC which is 190A and the start time is 11 seconds, after which the unit reverts to by-pass mode.

 

Features:

 

Simple compact smart solution, with graphical operation display on the SYMAP Compact protection relay. Showing the incoming voltage and the line and by-pass condition status and earth switch position.

The cabinet has an incoming disconnect and fuses, with a fault rating of 31.5kA for 1 second.

Soft starter provides starter feedback signals to the compressor panel, including motor current.

Smooth stress free starting no shock torque pulses, resulting in better mechanical life and lower current draw from the grid.